Brand Name : YUHONG

Model Number : C12200 , C44300, C68700, C70600

Certification : ABS, GL, DNV, NK, PED, AD2000, GOST9941-81, CCS, ISO 9001-2008

Place of Origin : CHINA

MOQ : 100KGS

Payment Terms : L/C, T/T

Delivery Time : 7DAYS

Packaging Details : Plywood Case /Iron Case/ Bundle/Woven Bag

MATERIAL : C12200 , C44300, C68700, C70600

WT : 0.89MM, 1MM, 1.24MM, 1.5MM, 1.65MM, 2MM, 2.11MM, 2.463MM, 2.5MM, 2.77MM, 3.05MM, 3.4MM

OD : 6.35MM , 9.52MM, 12.7MM , 15.88MM , 19.05MM, 20MM, 22,23MM, 25MM, 25.4MM , 31.75MM, 38.1MM , 44.45MM, 50.8MM , 63.5MM , 76.2MM, 88.9MM, 101.6MM, 152.4MM

TYPE : Straight Tube & U Bend Tube

INSPECTION : ET, HT, UT , PMI

STANDARD : ASTM B111, ASTM B88, ASTM B288 , ASTM B688

Contact Now

Copper Alloy Steel C12200 C70600 For Heat Exchanger Bundle With Tubesheet

Tube Bundle: The collection of tubes, tube sheets, and baffles is often referred to as the tube bundle. It is the core heat transfer section of the heat exchanger, and it can be removed for maintenance and cleaning purposes.:

Copper Alloy Steel C12200 C70600 For Heat Exchanger Bundle With Tubesheet

Standards
Cupro Nickel Tube90/ 10 Standard BS2871part3 ASTM B-111 IS 1545 JIS H 3300 NFA 51 102
Symbol CN 102 C 70600 CuNi10Fe1 C7060 CuNi10Fe1Mn
Cupro Nickel Tubes 70/30 Standard BS2871part3 ASTM B-111 IS 1545 JIS H 3300 NFA 51 102
NFA 51 102 CN 107 C 71500 CuNi30Mn1Fe C 7150 CuNi30Mn1Fe

Tube Sizes for Heat Exchangers & Condensers & Boiler
                   
Outside Diameter   BWG
25 22 20 18 16 14 12 10
  Wall Thickness mm
0.508 0.71 0.89 1.24 1.65 2.11 2.77 3.40
mm inch   Weight kg/m
6.35 1/4 0.081 0.109 0.133 0.174 0.212      
9.53 3/8 0.126 0.157 0.193 0.257 0.356 0.429    
12.7 1/2   0.214 0.263 0.356 0.457 0.612 0.754  
15.88 5/8   0.271 0.334 0.455 0.588 0.796 0.995  
19.05 3/4   0.327 0.405 0.553 0.729 0.895 1.236  
25.4 1   0.44 0.546 0.75 0.981 1.234 1.574 2.05
31.75 1 1/4   0.554 0.688 0.947 1.244 1.574 2.014 2.641
38.1 1 1/2   0.667 0.832 1.144 1.514 1.904 2.454 3.233
44.5 1 3/4       1.342 1.774 2.244 2.894 3.5
50.8 2       1.549 2.034 2.574 3.334 4.03
63.5 2 1/2       1.949 2.554 3.244 4.214 5.13
76.2 3       2.345 3.084 3.914 5.094 6.19
88.9 3 1/2       2.729 3.609 4.584 5.974 7.27
101.6 4         4.134 5.254 6.854 8.35
114.3 4 1/2         4.654 5.924 7.734 9.43

Copper Nickel Tubes 90/10 for Heat Exchangers & Condensers
These Copper Nickel tubes & pipes for Heat Exchangers & Condensers are very important for all Industrial fields. The company has experience in these areas and is able to supply these tubes in accordance with most international standards and special customer requirements.

Size Range:

Production Outside Diameter Wall Thickness
Heat Exchanger Tube 6.00mm to 101.6mm 0.5mm to 8mm

Final Finishing

Solution Annealed & Pickled/Bright Annealed.

Type of Tubes:

U-bend & Straight.

Some of the quality tests carried out by us includes:

Corrosion Test Conducted only when specially requested by the client
Chemical Analysis Test done as per required quality standards
Destructive / Mechanical Testing Tensile | Hardness | Flattening | Flare | Flange
Reverse-bend and Re. flat tests Carried out in full compliance with relevant standards & ASTM A-450 and A-530 norms, which ensures trouble-free expansion, welding & use at customers end
Eddy Current Testing Done to detect homogeneities in subsurface by using Digital Flaw-mark Testing System
Hydrostatic Testing 100% Hydrostatic Testing carried out according to ASTM-A 450 norms for checking tube leakage, and biggest pressure we can support 20Mpa/7s .
Air Under Pressure Test To check any evidence of air leakage
Visual Inspection After passivation, every single length of tubes & pipes is subjected to thorough visual inspection by trained staff for detecting surface flaws & other imperfections


Supplementary Testing : Apart from the above mentioned tests, we also carry out on the manufactured products supplementary testing. The tests conducted under this include:

  • Eddy Current Testing
  • O.P Testing
  • Radiography Testing
  • Corrosion Testing
  • Micro Testing
  • Macro Testing
  • IGC Testing
  • Ultrasonic testing
  • Liquid Penetrate testing

Copper Alloy Steel C12200 C70600 For Heat Exchanger Bundle With Tubesheet


China Copper Alloy Steel C12200 C70600 For Heat Exchanger Bundle With Tubesheet wholesale

Copper Alloy Steel C12200 C70600 For Heat Exchanger Bundle With Tubesheet Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Yuhong Group Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)